Steel conducts heat roughly 300 to 500 times faster than timber. In a steel frame wall, the studs act as thermal highways — heat flows through the steel faster than it flows through the insulation beside it. This is called thermal bridging, and it is the single biggest challenge steel frame homes face when targeting the 7-star NatHERS rating.
NatHERS assessment software (FirstRate5, AccuRate, BERS Pro) accounts for thermal bridging through steel frames using correction factors. When a steel frame is specified in the model, the software reduces the effective R-value of the wall assembly. The impact varies by stud size and spacing:
| Wall Assembly | Batt R-Value | Effective Wall R-Value | Performance Loss |
|---|---|---|---|
| Timber frame, 90mm studs @ 600mm | R2.5 | R2.2 | 12% |
| Steel frame, 89mm studs @ 600mm | R2.5 | R1.5 | 40% |
| Steel frame + thermal break strip | R2.5 | R2.0–R2.2 | 12–20% |
| Steel frame + external insulation board | R2.5 + R1.0 | R2.8–R3.2 | Minimal |
In practical terms, unmitigated thermal bridging in a steel frame home can cost 1.0 to 1.5 stars in the NatHERS rating compared to an identical timber frame home. In Climate Zones 6, 7 and 8 (Melbourne, Hobart, alpine areas), this is often the difference between passing and failing the 7-star requirement.
Thin strips of low-conductivity material (typically closed-cell foam, neoprene, or engineered polymer) applied to the external flange of each steel stud before wall wrap and cladding are installed. They interrupt the direct metal-to-cladding-fixing heat path.
Thermal break strips are the most common and cost-effective solution for steel frame kit homes. They do not change the wall thickness or cladding installation method.
A rigid insulation board (XPS, EPS, PIR, or phenolic foam) installed over the entire external face of the frame, outboard of the wall wrap. This creates a continuous thermal blanket with no gaps at studs.
External insulation is the highest-performing solution but adds wall thickness and requires longer cladding fixings. It is common in Zone 7 and 8 builds where maximum thermal performance is needed.
Engineered battens made from low-conductivity material that serve as both the NCC 2025 ventilated cavity spacer and a thermal break. These solve two problems with one product.
For builds in Climate Zones 6-8 where the ventilated cavity is mandatory from May 2026, thermal break cavity battens are the most efficient option because they eliminate one layer of installation.
Some steel frame manufacturers offer studs with integrated thermal breaks — a thin strip of non-conductive material laminated between the internal and external flanges of the stud. This breaks the thermal path within the stud itself.
| Climate Zone | Areas | Recommended Approach | Estimated Wall R-value Achieved |
|---|---|---|---|
| Zone 1-3 | Darwin, Cairns, Brisbane, coastal QLD | Thermal break strips (basic) or none required | R1.5–R2.0 |
| Zone 4-5 | Sydney, Perth, Adelaide, inland NSW | Thermal break strips + R2.5 batts | R2.0–R2.3 |
| Zone 6 | Melbourne, Geelong, Ballarat, ACT | Thermal break strips or cavity battens + R2.7 batts | R2.2–R2.6 |
| Zone 7 | Hobart, Canberra, highlands | External insulation board or cavity battens + R3.0 batts | R2.8–R3.5 |
| Zone 8 | Alpine areas | External insulation board + R3.0+ batts | R3.5+ |
For a typical 150m² kit home with approximately 180m² of external wall area:
| Solution | Material Cost | Labour | Total (approx) |
|---|---|---|---|
| Thermal break strips only | $800–$1,600 | $400–$800 | $1,200–$2,400 |
| Thermal break cavity battens | $2,500–$4,000 | $1,000–$1,800 | $3,500–$5,800 |
| Continuous external insulation (20mm) | $2,700–$5,000 | $1,500–$2,500 | $4,200–$7,500 |
| Continuous external insulation (40mm) | $4,500–$7,200 | $2,000–$3,500 | $6,500–$10,700 |
These costs are typically offset by savings elsewhere. A well-detailed thermal break strategy reduces the need for premium glazing upgrades or oversized insulation batts. The cheapest path to 7 stars in a steel frame home is almost always thermal breaks plus standard double glazing — not skipping thermal breaks and trying to compensate with triple glazing or exotic insulation.
BRIbuild steel frame kits are designed with thermal bridging accounted for at the drafting stage. Thermal break positions specified on every drawing.
View Floor Plans →Or call 1300 866 131